Please use this identifier to cite or link to this item: https://app.uff.br/riuff/handle/1/10560
Title: Avaliação da cimentação adesiva de ligas metálicas ao dente humano através de teste de cisalhamento
Authors: Hayassy, Armando
metadata.dc.contributor.advisor: Fraga, Ricardo Carvalhaes
Issue Date: 2011
Abstract: Este trabalho teve como finalidade avaliar a união de duas ligas metálicas, níquel-cromo e níquel-cromo-berílio aos dentes cimentados com quatro cimentos resinosos, Panávia Ex, Enforce, Variolink e Fill Magic Dual através de teste de cisalhamento. Foram tratados 40 cilindros de 6 mm por 4 de diâmetro por método de jateamento e cimentados a superfície vestibular de 40 dentes preparados com 1,0 mm em dentina. Os corpos de prova foram divididos em 4 grupos de 10 para utilização dos cimentos, sendo que de 10 foram divididos por 2 para diferenciar as ligas. Após cimentação, seguindo a orientação de cada fabricante, os corpos de prova foram armazenados por 7 dias em umidade relativa a 100%. Depois foram submetidos ao teste de cisalhamento. Obtidos os resultados e analisando-os estatisticamente, foi possível concluir que não houve diferença significativa considerando o poder de adesão, entre os cimentos usados nas duas ligas testadas.
metadata.dc.description.abstractother: This work has as main target to evaluate and compare the shear bond between two metal alloys (Ni-Cr and Ni-Cr-Be) cemented to teeth with four different luting agents (Panávia-Ex, Enforce, Conspan and Vivadent) through a shearing test. Forty cilinders of 6 mm hight and 4 mm in diameter have undergone a jet treatment and have been cemented to the surface of forty teeth wich had had their dentin previously hollowed in 1,0 mm. The test specimens were divided into four groups of ten so that if could be tested each one of the cements, and, in turn, each group was divided into two other groups of five in order to vary the alloys. After cementation, according to manufactures directions, the test specimens were kept during seven days under a 100% relative humidity. Following this period the shearing force tests took place. The results were statistically analised leading us to the conclusion there is no significative difference among the luting agents and metal alloys when considering the union power.
URI: https://app.uff.br/riuff/handle/1/10560
Appears in Collections:PPGO - Teses e Dissertações

Files in This Item:
File Description SizeFormat 
Dissertação Armando Hayassy.pdf587.33 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons